11#ifndef ISOBUS_STANDARD_DATA_DESCRIPTION_INDICES_HPP
12#define ISOBUS_STANDARD_DATA_DESCRIPTION_INDICES_HPP
This namespace encompasses all of the ISO11783 stack's functionality to reduce global namespace pollu...
DataDescriptionIndex
Enumerates a subset of standard ISOBUS DDIs.
@ SetpointVolumePerAreaApplicationRate
Setpoint Application Rate specified as volume per area.
@ LastBaleAverageHydraulicPressure
The average actual value of the hydraulic pressure applied to the sides of the bale in the bale compr...
@ HydraulicOilTemperature
Temperature of fluid in the hydraulic system.
@ SetpointMassPerTimeApplicationRate
Setpoint Application Rate specified as mass per time.
@ ActualSeparationFanRotationalSpeed
Actual rotational speed of the fan used for separating product material from non product material.
@ CountPerAreaYield
Yield as count per area.
@ AuxiliaryValveScalingExtend
Factor to apply to AuxValveCommand PortFlowCommand. The scaling of the port flow relates to flow,...
@ MinimumCountPerAreaApplicationRate
Minimum Application Rate specified as count per area.
@ CondensedSectionOverrideState17_32
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ FrontPTOhours
The hours the Front PTO of the machine was running for the current Task.
@ MinimumApplicationRateOfAmmonium
Minimum application rate of Ammonium specified as a mass per area.
@ ActualSeedingDepth
Actual Seeding Depth of Device Element below soil surface, value increases with depth.
@ MaximumBaleHeight
Maximum Bale Height is only applicable to square baler.
@ GNSSInstallationType
The GNSS Installation Type DDE is used by the device to provide additional information about the type...
@ LifetimeIneffectiveTotalDistance
Entire Ineffective Total Distance of the device lifetime.
@ ActualDownForceAsForce
Actual Downforce as Force.
@ LifetimeLoadedTotalMass
Entire Yield Total Mass of the device lifetime.
@ MinimumBaleHeight
Minimum Bale Height is only applicable to square baler.
@ MaximumVolumePerAreaApplicationRate
Maximum Application Rate specified as volume per area.
@ SetpointVolumePerMassApplicationRate
Setpoint Application Rate specified as volume per mass.
@ DefaultMassPerTimeApplicationRate
Default Application Rate specified as mass per time.
@ MaximumCountPerTimeApplicationRate
Maximum Application Rate specified as count per time.
@ MaximumTankAgitationPressure
Maximum Tank Agitation Pressure for a stir system in a tank.
@ MinimumWorkingWidth
Minimum Working Width of Device Element.
@ SetpointSpeed
The setpoint speed that can be specified in a process data variable for communication between farm ma...
@ MinimumMassPerTimeApplicationRate
Minimum Application Rate specified as mass per time.
@ SetpointGrainKernelCrackerGap
The setpoint gap (distance) of the grain kernel cracker drums in a chopper.
@ ThresherEngagementTotalTime
Accumulated time while the threshing mechanism is engaged.
@ LifetimeAverageDieselExhaustFluidConsumptionperArea
Average Diesel Exhaust Fluid Consumption per Area over the entire lifetime of the device.
@ SetpointCondensedWorkState129_144
The value is a combination of the setpoint work states of individual sections or units (e....
@ RearPTOhours
The hours the Rear PTO of the machine was running for the current Task.
@ MinimumCountPerTimeApplicationRate
Minimum Application Rate specified as count per time.
@ TotalApplicationOfDryMatter
Accumulated application of dry matter in kilogram [kg]. Dry matter measured at zero percent of moistu...
@ DefaultMassPerAreaApplicationRate
Default Application Rate specified as mass per area.
@ SetpointPercentageApplicationRate
Application Rate expressed as percentage.
@ TotalApplicationOfPhosphor
Accumulated application of phosphor (P2O5) specified as gram [g].
@ SetpointSpacingApplicationRate
Setpoint Application Rate specified as distance: e.g. seed spacing of a precision seeder.
@ AuxiliaryValveScalingRetract
Factor to apply to AuxValveCommand PortFlowCommand. The scaling of the port flow relates to flow,...
@ SetpointVolumePerTimeApplicationRate
Setpoint Application Rate specified as volume per time.
@ CropMoisture
Moisture in crop yield.
@ YieldLeadIgnoreTime
Amount of time to ignore yield data, starting at the transition from the out-of-work to the in-work s...
@ MaximumVolumeContent
Maximum Device Element Content specified as volume.
@ TotalApplicationOfAmmonium
Accumulated application of ammonium [NH4] specified as gram [g].
@ IneffectiveTotalTime
Accumulated Time out of working position.
@ PhysicalActualValueTimeLatency
The Actual Value Latency Time is the time lapse between the moment this actual value is communicated ...
@ MinimumSwathingWidth
This is the minimum swath width the raker can create.
@ FunctionOrOperationTechnique
The Function or Operation Technique DDE can be used to define the operation technique or functionalit...
@ UncutTotalCount
The total number of un-cut product units produced by a device during an operation.
@ ActualWorkState
Actual Work State, 2 bits defined as 00=disabled/off, 01=enabled/on, 10=error, 11=undefined/not insta...
@ ActualVolumePerMassApplicationRate
Actual Application Rate specified as volume per mass.
@ ProductDensityMassPerVolume
Product Density as mass per volume.
@ ActualEngineTorque
The current torque of the engine.
@ MaximumGrossWeight
Maximum Gross Weight specified as mass.
@ AverageSeedSkipPercentage
Average Seed Skip Percentage calculated from measured seed spacing using ISO 7256-1 "Miss Index" algo...
@ AuxiliaryValveFloatThreshold
Safety function. Current output of valve must be above threshold before float command is allowed.
@ ActualApplicationRateOfNitrogen
Actual application rate of nitrogen specified as a mass per area.
@ MinimumSieveClearance
Minimal separation distance between Sieve elements.
@ ActualPercentageCropDryMatter
Actual Percentage Crop Dry Matter expressed as parts per million.
@ MinimumChafferClearance
Minimum separation distance between Chaffer elements.
@ ActualTillageDepth
Actual Tillage Depth of Device Element below soil surface, value increases with depth....
@ MinimumSeedingDepth
Minimum Seeding Depth of Device Element below soil surface, value increases with depth.
@ ActualConcaveClearance
Actual separation distance between Concave elements.
@ AmbientTemperature
Ambient temperature measured by a machine. Unit is milli-Kelvin (mK).
@ AuxiliaryValveProgressivityExtend
Define non-linear relationship between command and flow by 2nd degree polynomial.
@ MinimumApplicationRateOfPotassium
Minimum application rate of potassium specified as a mass per area.
@ MaximumPercentageApplicationRate
Maximum Application Rate expressed as percentage.
@ SetpointCondensedWorkState225_240
The value is a combination of the setpoint work states of individual sections or units (e....
@ ActualBaleHeight
Actual Bale Height is only applicable to square baler.
@ SetpointCuttingDrumSpeed
The setpoint speed of the cutting drum of a chopper.
@ ApplicationTotalMass_kg
Accumulated Application specified as mass in kilogram [kg].
@ ActualCondensedWorkState177_192
Combination of the actual work states of individual sections or units (e.g. nozzles) number 177 to 19...
@ MaximumWorkingHeight
Maximum Working Height of Device Element above crop or soil.
@ MaximumConcaveClearance
Maximum separation distance between Concave elements.
@ MinimumWorkingLength
Minimum Working Length of Device Element.
@ ActualBaleSize
Actual Bale Size as length for a square baler or diameter for a round baler.
@ NozzleDriftReduction
The Nozzle Drift Reduction classification value of the spraying equipment as percentage.
@ LifetimeEffectiveTotalTime
Entire Effective Total Time of the device lifetime.
@ DefaultVolumePerVolumeApplicationRate
Default Application Rate specified as volume per volume.
@ ActualBaleWidth
Actual Bale Width for square baler or round baler.
@ MaximumVolumePerVolumeApplicationRate
Maximum Application Rate specified as volume per volume.
@ TotalApplicationOfNitrogen
Accumulated application of nitrogen [N2] specified as gram [g].
@ MinimumSpeed
The minimum speed that can be specified in a process data variable for communication between farm man...
@ DeviceCountCapacity
DeviceElement Count Capacity, dimension of a DeviceElement.
@ LintCottonMassPerAreaYield
Lint cotton yield as mass per area.
@ MinimumVolumePerVolumeApplicationRate
Minimum Application Rate specified as volume per volume.
@ LastBaleAppliedPreservative
The total preservative applied to the most recently produced bale.
@ ChopperEngagementTotalTime
Accumulated time while the chopping mechanism is engaged.
@ SkyConditions
This DDE is used to define the current sky conditions during operation. The METAR format and its abbr...
@ SpeedSource
The Speed Source that the device uses to report actual speed and to process the setpoint,...
@ TwineBaleTotalCount
The total number of twine bound product units for which Twine binding method was used during operatio...
@ UnloadIdentificationNumber
The Unload Identification Number as a decimal number in the range of 0 to 2147483647....
@ MinimumProductPressure
Minimum Product Pressure in the product flow system at the point of dispensing.
@ ActualRevolutionsPerTime
Actual Revolutions specified as count per time.
@ LastEventPartnerIDByte13_16
Last Event Partner ID as a decimal number of 128bit length.
@ MaximumRevolutionsPerTime
Maximum Revolutions specified as count per time.
@ MaximumMassContent
Maximum Device Element Content specified as mass.
@ MaximumSpacingApplicationRate
Maximum Application Rate specified as distance: e.g. seed spacing of a precision seeder.
@ SetpointVolumePerVolumeApplicationRate
Setpoint Application Rate specified as volume per volume.
@ VolumePerAreaCropLoss
Crop yield loss as volume per area.
@ EffectiveTotalDieselExhaustFluidConsumption
Accumulated total Diesel Exhaust Fluid consumption in working position.
@ ActualDieselExhaustFluidTankContent
The actual content of the diesel exhaust fluid tank.
@ ReferenceMoistureForDryMass
Moisture percentage used for the dry mass DDIs 181, 182 and 183.
@ ActualAtmosphericPressure
The Actual Atmospheric Pressure is the air pressure currently measured by the weather station.
@ MaximumProductPressure
Maximum Product Pressure in the product flow system at the point of dispensing.
@ ActualApplicationRateOfAmmonium
Actual application rate of Ammonium specified as a mass per area.
@ DefaultVolumePerTimeApplicationRate
Default Application Rate specified as volume per time.
@ VolumePerAreaYield
Yield as volume per area.
@ YieldTotalVolume
Accumulated Yield specified as volume.
@ LifetimeYieldTotalLintCottonMass
Entire Yield Total Lint Cotton Mass of the device lifetime.
@ ActualCondensedWorkState97_112
Combination of the actual work states of individual sections or units (e.g. nozzles) number 97 to 112...
@ CondensedSectionOverrideState193_208
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ InstantaneousFuelConsumptionPerTime
Fuel consumption per time.
@ SetpointPumpOutputPressure
Setpoint Pump Output Pressure to adjust the pressure at the output of the solution pump.
@ MinimumSeparationFanRotationalSpeed
Minimum rotational speed of the fan used for separating product material from non product material.
@ MaximumHeaderSpeed
The maximum rotational speed of the header attachment of a chopper, mower or combine.
@ DryMassPerTimeYield
Actual Dry Mass Per Time Yield. The definition of dry mass is the mass with a reference moisture spec...
@ DeviceElementOffsetZ
Z direction offset of a DeviceElement relative to a Device.
@ DefaultRevolutionsPerTime
Default Revolutions specified as count per time.
@ ActualFuelTankContent
The actual content of the fuel tank.
@ GNSSQuality
GNSS Quality Identifier to inform the implement about the used Position Status.
@ CondensedSectionOverrideState145_160
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ ActualTramlineCondensedWorkState1_16
Combination of the Actual States of individual Tramline Valves number 1 to 16 into a single Actual Tr...
@ MaximumEngineSpeed
The maximum of the rotational speed of the engine.
@ CondensedSectionOverrideState161_176
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ WindDirection
Wind direction measured in the treated field at the beginning of operations or on the application imp...
@ ActualCanopyHeight
Actual height of the canopy above ground.
@ ActualApplicationOfPotassium
Actual application of Potassium [K2] specified as gram [g].
@ MinimumTillageDepth
Minimum Tillage Depth of Device Element below soil surface, value increases with depth....
@ LintCottonMassPerTimeYield
Lint cotton yield as mass per time.
@ RemainingArea
Remaining Area of a field, which is calculated from the total area and the processed area.
@ SetpointProductPressure
Setpoint Product Pressure to adjust the pressure of the product flow system at the point of dispensin...
@ MinimumPercentageApplicationRate
Minimum Application Rate expressed as percentage.
@ SetpointCondensedWorkState113_128
The value is a combination of the setpoint work states of individual sections or units (e....
@ TramlineSequenceNumber
This DDI defines a group of DDIs which belong together.
@ MaximumBaleWidth
Maximum Bale Width for square baler or round baler.
@ MaximumCuttingDrumSpeed
The maximum speed of the cutting drum of a chopper.
@ MassPerTimeCropLoss
Crop yield loss as mass per time.
@ DefaultBaleHeight
Default Bale Height is only applicable to square baler.
@ RelativeYieldPotential
Relative yield potential provided by a FMIS or a sensor or entered by the operator for a certain task...
@ LifetimeHaulCounter
The number of haul cycles done by a machine over its entire lifetime.
@ MaximumVolumePerTimeApplicationRate
Maximum Application Rate specified as volume per time.
@ TotalApplicationOfPotassium
Accumulated application of potassium (K2) specified as gram [g].
@ LastLoadedVolume
Last loaded Volume value specified as volume.
@ GuidanceLineSwathWidth
The Swath Width is the Distance between two adjacent Guidance Lines in a Guidance Pattern.
@ SetpointSwathingWidth
This is the setpoint swathing width of the swath created by a raker.
@ CondensedSectionOverrideState225_240
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ SetpointFlakeSize
Setpoint size of the flake to be produced by the chamber.
@ LifetimeUnloadedTotalCount
Entire Unloaded Total Count of the device lifetime.
@ EffectiveTotalLoadingTime
The total time needed in the current task to load a product such as crop.
@ OperatingHoursSinceLastSharpening
This value describes the working hours since the last sharpening of the cutting device.
@ ActualLengthOfCut
Actual length of cut for harvested material, e.g. Forage Harvester or Tree Harvester.
@ ActualMassPerMassApplicationRate
Actual Application Rate specified as mass per mass.
@ AuxiliaryValveRampExtendUp
The valve will apply a ramp to the Auxiliary ValveCommand PortFlowCommand, to limit the acceleration ...
@ VolumePerTimeYield
Yield as volume per time.
@ ActualProteinContent
Actual Protein content of a harvested crops.
@ MaximumCountContent
Maximum Device Element Content specified as count.
@ DefaultTillageDepth
Default Tillage Depth of Device Element below soil surface, value increases with depth....
@ LastEventPartnerIDDeviceClass
This DDI should tell the Device Class of the Partner Device.
@ DefaultBaleSize
Default Bale Size as length for a square baler or diameter for a round baler.
@ AuxiliaryValveInvertPorts
Tell valve to swap extend and retract ports, easier than redoing plumbing on valve.
@ ActualEngineSpeed
Actual rotational speed of the engine.
@ LifetimeYieldTotalVolume
Entire Yield Total Volume of the device lifetime.
@ LastEventPartnerIDByte5_8
Last Event Partner ID as a decimal number of 128bit length.
@ ActualCondensedWorkState113_128
Combination of the actual work states of individual sections or units (e.g. nozzles) number 113 to 12...
@ SetpointCondensedWorkState193_208
The value is a combination of the setpoint work states of individual sections or units (e....
@ LogCount
Log Counter, may be used to control data log record generation on a Task Controller.
@ InstantaneousFuelConsumptionPerArea
Fuel consumption per area.
@ CondensedSectionOverrideState65_80
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ MaximumFlakeSize
Maximum size of the flake that can be produced by the chamber.
@ MaximumEngineTorque
The maximum value of the engine torque.
@ LoadedTotalMass
Accumulated Loads specified as mass, not corrected for the reference moisture percentage DDI 184.
@ MaximumApplicationRateOfAmmonium
Maximum application rate of Ammonium specified as a mass per area.
@ UniqueABGuidanceReferenceLineID
This DDI defines a unique ID to identify which Guidance Reference Line is the base for the Tramline c...
@ DefaultWorkingWidth
Default Working Width of Device Element.
@ SetpointNetWeight
Setpoint Net Weight value.
@ DeviceReferencePointDRPtoGroundDistance
This DDI is used to specify the distance from the Device Reference Point (DRP) down to the ground sur...
@ MinimumConcaveClearance
Minimum separation distance between Concave elements.
@ AverageDryYieldMassPerArea
Average Yield expressed as mass per unit area, corrected for the reference moisture percentage DDI 18...
@ ProductDensityMassPerCount
Product Density as mass per count.
@ UnloadedTotalVolume
Accumulated Unloaded Volume specified as volume.
@ EffectiveTotalTime
Accumulated Time in working position.
@ SeedCottonMassPerAreaYield
Seed cotton yield as mass per area, not corrected for a possibly included lint percentage.
@ InstantaneousDieselExhaustFluidConsumptionperArea
Diesel Exhaust Fluid consumption per area.
@ PGNBasedData
This DDI is used in the XML files to identify PGN based data.
@ SetpointDownforceasForce
Setpoint Downforce as Force.
@ ActualGrainKernelCrackerGap
The actual gap (distance) of the grain kernel cracker drums in a chopper.
@ MassPerAreaYield
Yield as mass per area, not corrected for the reference moisture percentage DDI 184.
@ PercentageCropLoss
Crop yield loss.
@ AverageSeedSingulationPercentage
Average Seed Singulation Percentage calculated from measured seed spacing using ISO 7256-1 "Quality o...
@ SetpointBaleWidth
Setpoint Bale Width for square baler or round baler.
@ ActualNormalizedDifferenceVegetativeIndexNDVI
The Normalized Difference Vegetative Index (NDVI) computed from crop reflectances.
@ TotalRevolutionsInCompleteRevolutions
Accumulated Revolutions specified as completed integer revolutions.
@ SetpointSieveClearance
Setpoint separation distance between Sieve elements.
@ ActualSeedSkipPercentage
Actual Seed Skip Percentage calculated from measured seed spacing using ISO 7256-1 "Miss Index" algor...
@ TotalEngineHours
The total time the engine was running when the task was active.
@ ActualCondensedWorkState49_64
Combination of the actual work states of individual sections or units (e.g. nozzles) number 49 to 64 ...
@ LifetimeFuelConsumption
Entire Fuel Consumption of the device lifetime.
@ ActualChafferClearance
Actual separation distance between Chaffer elements.
@ ActualCondensedWorkState241_256
Combination of the actual work states of individual sections or units (e.g. nozzles) number 241 to 25...
@ SetpointCondensedWorkState81_96
The value is a combination of the setpoint work states of individual sections or units (e....
@ ActualGrossWeight
Actual Gross Weight value specified as mass.
@ ActualPercentageApplicationRate
Actual Application Rate expressed as percentage.
@ LifetimeMeshBaleTotalCount
Entire total number of mesh product units for which Net binding method was used during operation,...
@ TramlineControlLevel
This DDI defines the Tramline Control capability of the Implement.
@ MaximumWorkingWidth
Maximum Working Width of Device Element.
@ SetpointLengthOfCut
Setpoint length of cut for harvested material, e.g. Forage Harvester or Tree Harvester.
@ TrackNumberToTheLeft
This DDI defines a unique number of the Guidance Track to left hand side in direction of Implement or...
@ ActualApplicationOfPhosphor
Actual application of Phosphor [P2O5] specified as milligram per liter [mg/l].
@ SetpointCountPerAreaApplicationRate
Setpoint Application Rate specified as count per area.
@ MinimumTankAgitationPressure
Minimum Tank Agitation Pressure for a stir system in a tank.
@ CropContamination
Dirt or foreign material in crop yield.
@ CondensedSectionOverrideState177_192
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ DeviceMassCapacity
DeviceElement Mass Capacity, dimension of a DeviceElement.
@ DieselExhaustFluidTankPercentageLevel
The actual level of the Diesel Exhaust Fluid Tank in percent.
@ MinimumWorkingHeight
Minimum Working Height of Device Element above crop or soil.
@ ConnectorPivotXOffset
X direction offset of a connector pivot point relative to DRP.
@ ActualMassContent
Actual Device Element Content specified as mass.
@ UnloadedTotalCount
Accumulated Unloaded specified as count.
@ AverageYieldMassPerTime
Average Yield expressed as mass per unit time, not corrected for the reference moisture percentage DD...
@ SetpointWorkingLength
Setpoint Working Length of Device Element.
@ ActualRelativeConnectorAngle
The DDI Actual relative connector angle shall be placed in the device element of type connector in th...
@ SetpointTramlineControlLevel
This DDI defines the Tramline Control capability of the Task Controller that is used with the appropr...
@ LastBaleFlakesPerBale
The number of flakes in the most recently produced bale.
@ SetpointMassContent
Setpoint Machine Element Content specified as mass.
@ YieldTotalDryMass
Accumulated Yield specified as dry mass. The definition of dry mass is the mass with a reference mois...
@ ElementTypeInstance
This DDI is used to enumerate and identify multiple device elements (DET) of the same type within one...
@ AverageSeedMultiplePercentage
Average Seed Multiple Percentage calculated from measured seed spacing using ISO 7256-1 "Multiples In...
@ LifetimeYieldTotalDryMass
Entire Yield Total Dry Mass of the device lifetime.
@ LifetimeThreshingEngagementTotalTime
Entire Threshing Engagement Total Time of the device lifetime.
@ AverageProteinContent
Average protein content in a harvested crop.
@ ActualSieveClearance
Actual separation distance between Sieve elements.
@ ActualSpacingApplicationRate
Actual Application Rate specified as distance: e.g. seed spacing of a precision seeder.
@ EffectiveTotalUnloadingTime
The total time needed in the current task to unload a product crop.
@ LoadedTotalCount
Accumulated Loads specified as count.
@ ApplicationTotalVolume_L
Accumulated Application specified as volume in liter [L].
@ MinimumApplicationRateOfNitrogen
Minimum application rate of nitrogen specified as a mass per area.
@ SetpointCondensedWorkState49_64
The value is a combination of the setpoint work states of individual sections or units (e....
@ YieldTotalSeedCottonMass
Accumulated yield specified as seed cotton mass, not corrected for a possibly included lint percentag...
@ LastUnloadedCount
Last unloaded Count value specified as count.
@ LifetimeRearPTOHours
The hours the Rear PTO of the machine was running for the lifetime of the machine.
@ PrescriptionControlState
Defines and synchronizes the actual state of the prescription system.
@ LastBaleMass
The mass of the bale that has most recently been produced.
@ SetpointCondensedWorkState97_112
The value is a combination of the setpoint work states of individual sections or units (e....
@ PitchAngle
Pitch Angle of a DeviceElement.
@ IneffectiveTotalDieselExhaustFluidConsumption
Accumulated total Diesel Exhaust Fluid consumption in non working position.
@ CountPerTimeCropLoss
Crop yield loss as count per time.
@ ActualVolumeContent
Actual Device Element Content specified as volume.
@ LifetimeAverageDieselExhaustFluidConsumptionperTime
Average Diesel Exhaust Fluid Consumption per Time over the entire lifetime of the device.
@ SetpointMassPerAreaApplicationRate
Setpoint Application Rate specified as mass per area.
@ MaximumDieselExhaustFluidTankContent
This value describes the maximum amount of Diesel Exhaust fluid, that can be filled into the tank of ...
@ MaximumApplicationRateOfDryMatter
Maximum application rate of dry matter expressed as percentage.
@ ActualCondensedWorkState81_96
Combination of the actual work states of individual sections or units (e.g. nozzles) number 81 to 96 ...
@ SetpointCondensedWorkState1_16
The value is a combination of the setpoint work states of individual sections or units (e....
@ CropTemperature
Temperature of harvested crop.
@ YieldTotalLintCottonMass
Accumulated yield specified as lint cotton mass.
@ ActualCoefficientofVariationofSeedSpacingPercentage
Actual Coefficient of Variation of Seed Spacing Percentage calculated from measured seed spacing usin...
@ SetpointApplicationRateOfDryMatter
Setpoint application rate of dry matter expressed as percentage.
@ DataDictionaryVersion
This DDE is used to specify which version of the Data Dictionary is being used.
@ SetpointMaximumAllowedSeedSpacingDeviation
Setpoint Maximum Allowed Seed Spacing Deviation.
@ CountPerAreaCropLoss
Crop yield loss as count per area.
@ MinimumRelativeYieldPotential
Minimum potential yield expressed as percentage.
@ ActualCountPerTimeApplicationRate
Actual Application Rate specified as count per time.
@ ActualSwathingWidth
This is the width of the swath currently created by a raker.
@ SCTurnOffTime
The Section Control Turn Off Time defines the overall time lapse between the moment the TC sends a tu...
@ ActualWorkingWidth
Actual Working Width of Device Element.
@ SetpointCondensedWorkState33_48
The value is a combination of the setpoint work states of individual sections or units (e....
@ SetpointEngineTorque
The setpoint of the engine torque.
@ InstantaneousAreaPerTimeCapacity
Area per time capacity.
@ MinimumRevolutionsPerTime
Minimum Revolutions specified as count per time.
@ LifetimeIneffectiveTotalTime
Entire Ineffective Total Time of the device lifetime.
@ MaximumApplicationRateOfPotassium
Maximum application rate of potassium specified as a mass per area.
@ LastEventPartnerIDType
Defines The Type of the Partner ID Device. See Attachment for Definition.
@ NumberOfSubUnitsPerSection
Specifies the number of sub-units for a section (e.g. number of nozzles per sprayer section or number...
@ LifetimeApplicationTotalCount
Entire Application Total Count of the device lifetime.
@ TotalArea
Accumulated Area.
@ LintTurnoutPercentage
Percent of lint in the seed cotton.
@ PrecutTotalCount
The total number of pre-cut product units produced by a device during an operation.
@ IneffectiveTotalDistance
Accumulated Distance out of working position.
@ SetpointBaleCompressionPlungerLoad
The setpoint bale compression plunger load as a unitless number.
@ YieldTotalMass
Accumulated Yield specified as mass, not corrected for the reference moisture percentage DDI 184.
@ YawAngle
Pivot / Yaw Angle of a DeviceElement.
@ LoadedTotalVolume
Accumulated Loaded Volume specified as volume.
@ SetpointBaleHeight
Setpoint Bale Height is only applicable to square baler.
@ LifetimeYieldTotalCount
Entire Yield Total Count of the device lifetime.
@ TramlineControlState
Specifies the actual state of Tramline Control. See isobus.net.
@ TrueRotationPointXOffset
X direction offset of the device rotation point relative to the DRP.
@ ActualSpeed
The actual speed as measured on or used by a device for the execution of task based data,...
@ LastUnloadedWeight
Last unloaded Weight value specified as mass.
@ LifetimeAverageFuelConsumptionPerTime
Entire Average Fuel Consumption per Time of the device lifetime.
@ ActualCondensedWorkState129_144
Combination of the actual work states of individual sections or units (e.g. nozzles) number 129 to 14...
@ LastBaleAverageStrokesPerFlake
The number of baler plunger compression strokes per flake that has entered the bale compression chamb...
@ GrossWeightState
Gross Weight State.
@ LastBaleSize
The bale size of the most recently produced bale. Bale Size as length for a square baler or diameter ...
@ MaximumWorkingLength
Maximum Working Length of Device Element.
@ SetpointTankAgitationPressure
Setpoint Tank Agitation Pressure to adjust the pressure for a stir system in a tank.
@ MaximumCountPerAreaApplicationRate
Maximum Application Rate specified as count per area.
@ SetpointCondensedWorkState161_176
The value is a combination of the setpoint work states of individual sections or units (e....
@ DefaultVolumePerAreaApplicationRate
Default Application Rate specified as volume per area.
@ SetpointVolumeContent
Setpoint Device Element Content specified as volume.
@ YieldTotalCount
Accumulated Yield specified as count.
@ ActualApplicationOfDryMatter
Actual application of Dry Matter in kilogram [kg]. Dry matter measured at Zero percent of moisture.
@ MaximumMassPerMassApplicationRate
Maximum Application Rate specified as mass per mass.
@ MaximumGrainKernelCrackerGap
The maximum gap (distance) of the grain kernel cracker drums in a chopper.
@ HaulCounter
Each Time a Device Element is filled and emptied this is called a haul cycle. This counter counts the...
@ AveragePercentageCropDryMatter
Average Percentage Crop Dry Matter expressed as parts per million.
@ AverageCoefficientofVariationofSeedSpacingPercentage
Average Coefficient of Variation of Seed Spacing Percentage calculated from measured seed spacing usi...
@ MinimumEngineSpeed
The minimum of the rotational speed of the engine.
@ MassPerTimeYield
Yield as mass per time, not corrected for the reference moisture percentage DDI 184.
@ TotalRevolutionsInFractionalRevolutions
Accumulated Revolutions specified with fractional revolutions.
@ AuxiliaryValveRampRetractDown
The valve will apply a ramp to the Auxiliary ValveCommand PortFlowCommand, to limit the acceleration ...
@ MeshBaleTotalCount
The total number of mesh product units for which Net binding method was used during operation.
@ DefaultSeedingDepth
Default Seeding Depth of Device Element below soil surface, value increases with depth.
@ LifetimePrecutTotalCount
Entire Precut Total Count of the device lifetime.
@ LifetimeAverageFuelConsumptionPerArea
Entire Average Fuel Consumption per Area of the device lifetime.
@ LastBaleLifetimeCount
The Lifetime Bale Count of the bale that leaves the machine. The value shall be equal to the Lifetime...
@ SetpointMassPerMassApplicationRate
Setpoint Application Rate specified as mass per mass.
@ SetpointHeaderSpeed
The setpoint rotational speed of the header attachment of a chopper, mower or combine.
@ ActualHeaderWorkingHeightStatus
Actual status of the header being above or below the threshold height for the in-work state.
@ LifetimeFrontPTOhours
The hours the Front PTO of the machine was running for the lifetime of the machine.
@ ApparentWindDirection
The apparent wind is the wind which is measured on a moving vehicle. It is the result of two motions:...
@ TramlineOverdosingRate
Overdosing Rate for the rows adjacent to the Tramline Track.
@ ApparentWindSpeed
The apparent wind is the wind which is measured on a moving vehicle. It is the result of two motions:...
@ MinimumEngineTorque
The minimum value of the engine torque.
@ AuxiliaryValveProgressivityRetract
Define non-linear relationship between command and flow by 2nd degree polynomial.
@ SectionControlState
Specifies the actual state of section control.
@ MaximumSpeed
The maximum speed that can be specified in a process data variable for communication between farm man...
@ MinimumHeaderSpeed
The minimum rotational speed of the header attachment of a chopper, mower or combine.
@ SetpointCondensedWorkState241_256
The value is a combination of the setpoint work states of individual sections or units (e....
@ LastEventPartnerIDByte1_4
Last Event Partner ID as a decimal number of 128bit length.
@ TotalBaleLength
Gives the total baled meters during a task. This is calculated as the sum of the lengths of all knott...
@ DefaultSpacingApplicationRate
Default Application Rate specified as distance: e.g. seed spacing of a precision seeder.
@ WindSpeed
Wind speed measured in the treated field at the beginning of operations or on the application impleme...
@ ActualHeaderRotationalSpeedStatus
Actual status of the header rotational speed being above or below the threshold for in-work state.
@ ActualPrescriptionMode
This DDE defines the actual source of the set point value used by the Control Function.
@ MinimumMassPerMassApplicationRate
Minimum Application Rate specified as mass per mass.
@ MaximumTillageDepth
Maximum Tillage Depth of Device Element below soil surface, value increases with depth....
@ YieldLagIgnoreTime
Amount of time to ignore yield data, starting at the transition from the in-work to the out-of-work s...
@ LastBaleDensity
The bale density of the most recently produced bale. Unit : mg / l(mass per unit volume)
@ ActualCondensedWorkState225_240
Combination of the actual work states of individual sections or units (e.g. nozzles) number 225 to 24...
@ ActualApplicationOfAmmonium
Actual application of Ammonium [NH4] specified as milligram per liter [mg/l].
@ MaximumBaleHydraulicPressure
The maximum value of the hydraulic pressure applied to the sides of the bale in the bale compression ...
@ ActualBaleCompressionPlungerLoad
The actual bale compression plunger load as a unitless number.
@ MinimumBaleHydraulicPressure
The minimum value of the hydraulic pressure applied to the sides of the bale in the bale compression ...
@ ActualCondensedWorkState1_16
Combination of the actual work states of individual sections or units (e.g. nozzles) number 1 to 16 i...
@ DeviceElementOffsetY
Y direction offset of a DeviceElement relative to a Device.
@ MinimumMassPerAreaApplicationRate
Minimum Application Rate specified as mass per area.
@ SetpointSeparationFanRotationalSpeed
Setpoint rotational speed of the fan used for separating product material from non product material.
@ ActualCondensedWorkState33_48
Combination of the actual work states of individual sections or units (e.g. nozzles) number 33 to 48 ...
@ LifetimeUncutTotalCount
Entire Uncut Total Count of the device lifetime.
@ DryMassPerAreaYield
Actual Dry Mass Per Area Yield. The definition of dry mass is the mass with a reference moisture spec...
@ ActualVolumePerAreaApplicationRate
Actual Application Rate specified as volume per area.
@ SetpointCountContent
Setpoint Device Element Content specified as count.
@ PhysicalObjectLength
Length of device element (dimension along the X-axis)
@ LifetimeEffectiveTotalDistance
Entire Total Distance of the device lifetime.
@ PhysicalObjectWidth
Width of device element (dimension along the Y-axis)
@ MaximumLengthOfCut
Maximum length of cut for harvested material, e.g. Forage Harvester or Tree Harvester.
@ TrackNumberToTheRight
This DDI defines a unique number of the Guidance Track to right hand side in direction of Implement o...
@ ActualCondensedWorkState145_160
Combination of the actual work states of individual sections or units (e.g. nozzles) number 145 to 16...
@ SetpointSeedingDepth
Setpoint Seeding Depth of Device Element below soil surface, value increases with depth.
@ SetpointApplicationRateOfNitrogen
Setpoint application rate of nitrogen specified as a mass per area.
@ SetpointPrescriptionMode
This DDE defines the source of the Task Controller set point value sent to the Control Function.
@ LastLoadedCount
Last loaded Count value specified as count.
@ PhysicalSetpointTimeLatency
The Setpoint Value Latency Time is the time lapse between the moment of reception of a setpoint value...
@ LifetimeTwineBaleTotalCount
Entire total number of twine bound product units for which Twine binding method was used during opera...
@ SetpointCondensedWorkState145_160
The value is a combination of the setpoint work states of individual sections or units (e....
@ SetpointEngineSpeed
The setpoint of the rotational speed of the engine.
@ MinimumFlakeSize
Minimum size of the flake that can be produced by the chamber.
@ LifetimeYieldTotalMass
Entire Yield Total Mass of the device lifetime.
@ CondensedSectionOverrideState209_224
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ ActualUnLoadingSystemStatus
Actual status of the Unloading and/or Loading system. This DDE covers both Unloading and Loading of t...
@ ActualMassPerTimeApplicationRate
Actual Application Rate specified as mass per time.
@ GuidanceLineDeviation
Deviation of the Device-Reference-Point (DRP) to the actual guidance line, in driving direction.
@ LastEventPartnerIDByte9_12
Last Event Partner ID as a decimal number of 128bit length.
@ ActualSeedSpacingDeviation
Actual Seed Spacing Deviation from setpoint seed spacing.
@ CondensedSectionOverrideState241_256
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ ActualCulturalPractice
This DDI is used to define the current cultural practice which is performed by an individual device o...
@ SetpointWorkingHeight
Setpoint Working Height of Device Element above crop or soil.
@ FuelPercentageLevel
The actual level of the machine fuel tank in percent.
@ LastLoadedWeight
Last loaded Weight value specified as mass.
@ MinimumGrainKernelCrackerGap
The minimum gap (distance) of the grain kernel cracker drums in a chopper.
@ LifetimeLoadedTotalVolume
Entire loaded Volume of the device lifetime.
@ ActualSeedSingulationPercentage
Actual Seed Singulation Percentage calculated from measured seed spacing using ISO 7256-1 "Quality of...
@ CondensedSectionOverrideState129_144
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ SetpointCondensedWorkState17_32
The value is a combination of the setpoint work states of individual sections or units (e....
@ MinimumSpacingApplicationRate
Minimum Application Rate specified as distance: e.g. seed spacing of a precision seeder.
@ ActualVolumePerTimeApplicationRate
Actual Application Rate specified as volume per time.
@ ActualCondensedWorkState193_208
Combination of the actual work states of individual sections or units (e.g. nozzles) number 193 to 20...
@ LastBaleNumberofSubbales
Number of smaller bales included in the latest produced bale.
@ TotalDieselExhaustFluidConsumption
Accumulated Diesel Exhaust Fluid Consumption as a Task Total.
@ ActualPumpOutputPressure
Actual Pump Output Pressure measured at the output of the solution pump.
@ CountPerTimeYield
Yield as count per time.
@ LastEventPartnerIDManufacturerIDCode
The Partner ID has to tell its Manufacturer, and the Manufacturer Numbers from SAE J1939 / ISO 11783 ...
@ CondensedSectionOverrideState81_96
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ LastBaleAverageMoisture
The average moisture in the most recently produced bale.
@ MaximumVolumePerMassApplicationRate
Maximum Application Rate specified as volume per mass.
@ DefaultCountPerTimeApplicationRate
Default Application Rate specified as count per time.
@ ProductDensityVolumePerCount
Product Density as volume per count.
@ EffectiveTotalDistance
Accumulated Distance in working position.
@ SetpointWorkState
The Setpoint Work State DDI is the control command counterparts to the Work State DDI (141).
@ MinimumApplicationRateOfDryMatter
Minimum application rate of dry matter expressed as percentage.
@ SetpointCondensedWorkState65_80
The value is a combination of the setpoint work states of individual sections or units (e....
@ ActualCuttingDrumSpeed
The actual speed of the cutting drum of a chopper.
@ PhysicalObjectHeight
Height of device element (dimension along the Z-axis)
@ EffectiveTotalFuelConsumption
Accumulated total fuel consumption in working position.
@ MinimumGrossWeight
Minimum Gross Weight specified as mass.
@ MaximumChafferClearance
Maximum separation distance between Chaffer elements.
@ LifetimeUnloadedTotalVolume
Entire unloaded Volume of the device lifetime.
@ MaximumRelativeYieldPotential
Maximum potential yield expressed as percentage.
@ ActualSeedMultiplePercentage
Actual Seed Multiple Percentage calculated from measured seed spacing using ISO 7256-1 "Multiples Ind...
@ CondensedSectionOverrideState97_112
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ ActualTrackNumber
This DDI defines a unique number of the Guidance Track the Implement is currently located on.
@ DeviceVolumeCapacity
DeviceElement Volume Capacity, dimension of a DeviceElement.
@ MinimumVolumePerMassApplicationRate
Minimum Application Rate specified as volume per mass.
@ LoadIdentificationNumber
The Load Identification Number as a decimal number in the range of 0 to 4294967295....
@ MaximumSeedingDepth
Maximum Seeding Depth of Device Element below soil surface, value increases with depth.
@ ApplicationTotalVolume_ml
Accumulated Application specified as volume in milliliter [ml].
@ ConnectorType
Specification of the type of coupler. See isobus.net for the enumerated values.
@ ActualCoolingFluidTemperature
The actual temperature of the cooling fluid for the machine.
@ MinimumVolumePerTimeApplicationRate
Minimum Application Rate specified as volume per time.
@ ActualCondensedWorkState161_176
Combination of the actual work states of individual sections or units (e.g. nozzles) number 161 to 17...
@ MinimumLengthOfCut
Minimum length of cut for harvested material, e.g. Forage Harvester or Tree Harvester.
@ DefaultBaleWidth
Default Bale Width for square baler or round baler.
@ LifetimeEngineHours
The total time, when the engine was running over the whole lifetime of the machine.
@ AuxiliaryValveRampRetractUp
The valve will apply a ramp to theAuxiliary ValveCommand PortFlowCommand, to limit the acceleration o...
@ LifetimeYieldTotalSeedCottonMass
Entire Yield Total Seed Cotton Mass of the device lifetime.
@ SetpointBaleHydraulicPressure
The setpoint value of the hydraulic pressure applied to the sides of the bale in the bale compression...
@ AverageCropContamination
Average amount of dirt or foreign in a harvested crop.
@ LifetimeDieselExhaustFluidConsumption
Accumulated Diesel Exhaust Fluid Consumption over the entire lifetime of the device.
@ ApplicationTotalMassGram_g
Accumulated Application specified as mass in gram [g].
@ SetpointTillageDepth
Setpoint Tillage Depth of Device Element below soil surface, value increases with depth....
@ MassPerAreaCropLoss
Crop yield loss as mass per area.
@ ActualCondensedWorkState65_80
Combination of the actual work states of individual sections or units (e.g. nozzles) number 65 to 80 ...
@ RollAngle
Roll Angle of a DeviceElement.
@ ActualApplicationRateOfDryMatter
Actual application rate of dry matter expressed as percentage.
@ LifetimeBaleCount
The number of bales produced by a machine over its entire lifetime. This DDE value can not be set thr...
@ LastBaleDryMass
The dry mass of the bale that has most recently been produced. This is the bale mass corrected for th...
@ SetpointApplicationRateOfPhosphor
Setpoint application rate of phosphor specified as a mass per area.
@ TotalFuelConsumption
Accumulated Fuel Consumption as Counter.
@ ActualWorkingHeight
Actual Working Height of Device Element above crop or soil.
@ ActualCountContent
Actual Device Element Content specified as count.
@ SetpointApplicationRateOfAmmonium
Setpoint application rate of Ammonium specified as a mass per area.
@ UnloadedTotalMass
Accumulated Unloads specified as mass, not corrected for the reference moisture percentage DDI 184.
@ LifetimeApplicationTotalMass
Entire Application Total Mass of the device lifetime.
@ CondensedSectionOverrideState1_16
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ MinimumBaleSize
Minimum Bale Size as length for a square baler or diameter for a round baler.
@ LifetimeWorkingHours
The number of working hours of a device element over its entire lifetime. This DDE value can not be s...
@ SetpointDownForcePressure
Setpoint downforce pressure for an operation.
@ MinimumApplicationRateOfPhosphor
Minimum application rate of phosphor specified as a mass per area.
@ MaximumPumpOutputPressure
Maximum Pump Output Pressure for the output pressure of the solution pump.
@ ActualBaleHydraulicPressure
The actual value of the hydraulic pressure applied to the sides of the bale in the bale compression c...
@ AirHumidity
Ambient humidty measured by a weather station in a treated field or on the application implement.
@ LastBaleAverageBaleCompressionPlungerLoad
The average bale compression plunger load for the most recently produced bale.
@ NetWeightState
Net Weight State.
@ DeltaT
The difference between dry bulb temperature and wet bulb temperature measured by a weather station in...
@ ActualApplicationRateOfPhosphor
Actual application rate of phosphor specified as a mass per area.
@ SetpointCountPerTimeApplicationRate
Setpoint Application Rate specified as count per time.
@ MaximumSeparationFanRotationalSpeed
Maximum rotational speed of the fan used for separating product material from non product material.
@ SetpointTramlineCondensedWorkState1_16
The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tr...
@ ActualVolumePerVolumeApplicationRate
Actual Application Rate specified as volume per volume.
@ ActualCondensedWorkState209_224
Combination of the actual work states of individual sections or units (e.g. nozzles) number 209 to 22...
@ ApplicationTotalCount
Accumulated Application specified as count.
@ InstantaneousDieselExhaustFluidConsumptionperTime
Diesel Exhaust Fluid consumption per time.
@ LastBaleCapacity
The capacity of the bale that leaves the machine.
@ ActualMassPerAreaApplicationRate
Actual Application Rate specified as mass per area.
@ VolumePerTimeCropLoss
Crop yield loss as volume per time.
@ LastBaleTagNumber
The Last Bale Tag Number as a decimal number in the range of 0 to 4294967295. Note that the value of ...
@ CondensedSectionOverrideState33_48
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ DefaultCountPerAreaApplicationRate
Default Application Rate specified as count per area.
@ ActualWorkingLength
Actual Working Length of a Device Element.
@ AverageSeedSpacingDeviation
Average Seed Spacing Deviation from setpoint seed spacing. The value is the average for a Task.
@ ActualNetWeight
Actual Net Weight value specified as mass.
@ MaximumMassPerTimeApplicationRate
Maximum Application Rate specified as mass per time.
@ YieldHoldStatus
Status indicator for the yield measurement system. When enabled/on, the measurements from the yield m...
@ SCTurnOnTime
The Section Control Turn On Time defines the overall time lapse between the moment the TC sends a tur...
@ MaximumSieveClearance
Maximum separation distance between Sieve elements.
@ CondensedSectionOverrideState113_128
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ AuxiliaryValveRampExtendDown
The valve will apply a ramp to the Auxiliary ValveCommand PortFlowCommand, to limit the acceleration ...
@ ActualHeaderSpeed
The actual rotational speed of the header attachment of a chopper, mower or combine.
@ MinimumBaleWidth
Minimum Bale Width for square baler or round baler.
@ AverageYieldMassPerArea
Average Yield expressed as mass per unit area, not corrected for the reference moisture percentage DD...
@ ActualCondensedWorkState17_32
Combination of the actual work states of individual sections or units (e.g. nozzles) number 17 to 32 ...
@ DefaultMassPerMassApplicationRate
Default Application Rate specified as mass per mass.
@ DeviceElementOffsetX
X direction offset of a DeviceElement relative to a Device.
@ MaximumBaleSize
Maximum Bale Size as length for a square baler or diameter for a round baler.
@ MaximumFuelTankContent
This value describes the maximum amount of fuel that can be filled into the machines Fuel tank.
@ MaximumMassPerAreaApplicationRate
Maximum Application Rate specified as mass per area.
@ ActualCountPerAreaApplicationRate
Actual Application Rate specified as count per area.
@ LifetimeLoadedTotalCount
Entire Loaded Total Count of the device lifetime.
@ RequestDefaultProcessData
Request Default Process Data. This DDE is the highest ISO assigned entity. The range above this numbe...
@ MinimumPumpOutputPressure
Minimum Pump Output Pressure for the output pressure of the solution pump.
@ SetpointNumberofSubbales
Number of smaller bales that shall be included in one bigger bale.
@ MinimumCuttingDrumSpeed
The minimum speed of the cutting drum of a chopper.
@ SetpointBaleSize
Setpoint Bale Size as length for a square baler or diameter for a round baler.
@ ActualFlakeSize
Actual size of the flake that is currently produced by the chamber.
@ SetpointRevolutionsSpecifiedAsCountPerTime
Setpoint Revolutions specified as count per time.
@ AverageDryYieldMassPerTime
Average Yield expressed as mass per unit time, corrected for the reference moisture percentage DDI 18...
@ ActualApplicationOfNitrogen
Actual application of Nitrogen [N2] specified as milligram per liter [mg/l].
@ MaximumApplicationRateOfPhosphor
Maximum application rate of phosphor specified as a mass per area.
@ LifetimeTotalArea
Entire Total Area of the device lifetime.
@ MSLAtmosphericPressure
The atmospheric pressure MSL (Mean Sea Level) is the air pressure related to mean sea level.
@ ActualApplicationRateOfPotassium
Actual application rate of potassium specified as a mass per area.
@ ActualPercentageContent
Actual Device Element Content specified as percent.
@ SetpointCondensedWorkState209_224
The value is a combination of the setpoint work states of individual sections or units (e....
@ TrueRotationPointYOffset
Y direction offset of the device rotation point relative to the DRP.
@ SetpointCondensedWorkState177_192
The value is a combination of the setpoint work states of individual sections or units (e....
@ SetpointConcaveClearance
Setpoint separation distance between Concave elements.
@ SetpointChafferClearance
Setpoint separation distance between Chaffer elements.
@ MaximumSwathingWidth
This is the maximum with of the swath the raker can create.
@ MaximumApplicationRateOfNitrogen
Maximum application rate of nitrogen specified as a mass per area.
@ SetpointWorkingWidth
Setpoint Working Width of Device Element.
@ ActualDownForcePressure
Actual downforce pressure for an operation.
@ DefaultWorkingHeight
Default Working Height of Device Element above crop or soil.
@ IneffectiveTotalFuelConsumption
Accumulated total fuel consumption in non working position.
@ DefaultVolumePerMassApplicationRate
Default Application Rate specified as volume per mass.
@ SeedCottonMassPerTimeYield
Seed cotton yield as mass per time, not corrected for a possibly included lint percentage.
@ AverageCropMoisture
Average Moisture of the harvested crop. This value is the average for a Task and may be reported as a...
@ ActualTankAgitationPressure
Actual Tank Agitation Pressure measured by the tank stir system.
@ LifetimeUnloadedTotalMass
Entire Unloaded Total Mass of the device lifetime.
@ MinimumVolumePerAreaApplicationRate
Minimum Application Rate specified as volume per area.
@ CondensedSectionOverrideState49_64
This DDE is used by the implement to communicate that a certain section is overridden and will not fo...
@ SetpointApplicationRateOfPotassium
Setpoint application rate of potassium specified as a mass per area.
@ LifetimeApplicationTotalVolume
Entire Application Total Volume of the device lifetime.
@ LastUnloadedVolume
Last unloaded Volume value specified as volume.
@ ActualProductPressure
Actual Product Pressure is the measured pressure in the product flow system at the point of dispensin...